Manufacturer Packaging Series ProductStatus UserConfiguration Type NumberofPositions Voltage-Input Power(Watts) Voltage-Isolation Efficiency Features OperatingTemperature Size/Dimension Height ApprovalAgency








































































































































Reset All
Apply All
Results:
Mfr. Part # Stock Price Quantity Datasheet Packaging Series ProductStatus UserConfiguration Type NumberofPositions Voltage-Input Power(Watts) Voltage-Isolation Efficiency Features OperatingTemperature Size/Dimension Height ApprovalAgency
XLA-00

XLA-00

CONFIG POWER CHASSIS 200W 4 SLOT

Advanced Energy

7609 239.24
- +

Add To Cart

Inquiry Now

XLA-00

Datasheet

Bulk Xgen, XL Active - Standard 4 85 ~ 264 VAC 200 W 3 kV 89% - -20°C ~ 70°C 10.24 L x 3.50 W (260.0mm x 89.0mm) 1.59 (40.40mm) CE, cURus
XLC-D0

XLC-D0

CONFIGURABLE POWER SUPPLY

Advanced Energy

7806 257.38
- +

Add To Cart

Inquiry Now

XLC-D0

Datasheet

Box Xgen, XL Active - Standard, Low Noise 4 85 ~ 264 VAC 600 W 3 kV 89% Fan Fail, Temperature Alarm -20°C ~ 70°C (With Derating) 10.24 L x 3.50 W (260.0mm x 89.0mm) 1.59 (40.40mm) CE, cURus
UX4-D0

UX4-D0

CONFIG POWER CHASSIS

Advanced Energy

7611 257.40
- +

Add To Cart

Inquiry Now

UX4-D0 Box UltiMod, UX Active - Medical 4 85 ~ 264 VAC 600 W 4 kV 90% Fan Fail, Temperature Alarm -40°C ~ 70°C (With Derating) 10.24 L x 3.50 W (260.0mm x 89.0mm) 1.59 (40.40mm) CE
CX06S-0000-N1A

CX06S-0000-N1A

CONFIG POWER CHASSIS 600W 4 SLOT

Advanced Energy

7665 270.27
- +

Add To Cart

Inquiry Now

CX06S-0000-N1A

Datasheet

Bulk CoolX™600 NFF Active - Medical 4 85 ~ 264 VAC 600 W 4 kV 94% - -40°C ~ 85°C (With Derating) 8.50 L x 4.50 W (215.9mm x 114.3mm) 1.50 (38.1mm) CE
CX06S-0000-N-B

CX06S-0000-N-B

CONFIG POWER CHASSIS 600W 4 SLOT

Advanced Energy

8373 270.27
- +

Add To Cart

Inquiry Now

CX06S-0000-N-B

Datasheet

Box CoolX™600 NFF Active - Standard, Ultra Quiet 4 85 ~ 264 VAC 600 W 4 kV 93% - -40°C ~ 70°C (With Derating) 8.50 L x 4.50 W (215.9mm x 114.3mm) 1.54 (39.1mm) CE, cTUVus
XTB-01

XTB-01

CONFIG POWER CHASSIS 400W 4 SLOT

Advanced Energy

7286 314.33
- +

Add To Cart

Inquiry Now

XTB-01

Datasheet

Box Xgen, XT Active - Standard, Ultra Quiet 4 85 ~ 264 VAC 400 W 3 kV 90% Fan Fail, Temperature Alarm -20°C ~ 70°C 10.55 L x 3.50 W (268.0mm x 89.0mm) 1.59 (40.40mm) CE, cURus
CX06M-0000-N4A

CX06M-0000-N4A

CONFIG POWER CHASSIS 600W 4 SLOT

Advanced Energy

8424 338.74
- +

Add To Cart

Inquiry Now

CX06M-0000-N4A

Datasheet

Bulk CoolX™600 NFF Active - Medical 4 85 ~ 264 VAC 600 W 4 kV 94% - -40°C ~ 85°C (With Derating) 8.50 L x 4.50 W (215.9mm x 114.3mm) 1.50 (38.1mm) CE
XNB-05

XNB-05

CONFIG POWER CHASSIS

Advanced Energy

7117 368.75
- +

Add To Cart

Inquiry Now

XNB-05 Box Xgen, XN Active - Medical, Ultra Quiet 4 85 ~ 264 VAC 400 W 4 kV 89% Fan Fail, Temperature Alarm -20°C ~ 70°C (With Derating) 10.24 L x 3.50 W (260.0mm x 89.0mm) 1.59 (40.40mm) CE, cURus
XCCC0

XCCC0

CONFIGURABLE POWER SUPPLY

Advanced Energy

8636 395.41
- +

Add To Cart

Inquiry Now

XCCC0

Datasheet

Box Xgen, XC Active - Standard 6 85 ~ 264 VAC 1000 W 3 kV 90% Fan Fail, Temperature Alarm -20°C ~ 70°C (With Derating) 10.24 L x 5.00 W (260.0mm x 127.0mm) 1.59 (40.40mm) CE, cURus
CX18S-000000-N1B

CX18S-000000-N1B

CONFIG POWER CHASSIS 1800W 6 SLO

Advanced Energy

6989 432.43
- +

Add To Cart

Inquiry Now

CX18S-000000-N1B

Datasheet

Bulk CoolX™1800 Active - Standard 6 85 ~ 264 VAC 1800 W 4 kV 91% - -40°C ~ 70°C (With Derating) 10.31 L x 5.00 W (262.0mm x 127.0mm) 1.60 (40.6mm) CE
CX10M-000000-N-B

CX10M-000000-N-B

CONFIG POWER CHASSIS 1000W 6 SLO

Advanced Energy

8706 471.74
- +

Add To Cart

Inquiry Now

CX10M-000000-N-B

Datasheet

Bulk CoolX™1000 Active - Medical 6 85 ~ 264 VAC 1000 W 4 kV 93% - -40°C ~ 85°C (With Derating) 10.00 L x 6.50 W (254.0mm x 165.1mm) 1.60 (40.6mm) cCSAus, CE
CX10M-000000-N-A

CX10M-000000-N-A

CONFIG POWER CHASSIS 1000W 6 SLO

Advanced Energy

7198 471.74
- +

Add To Cart

Inquiry Now

CX10M-000000-N-A

Datasheet

Bulk CoolX™1000 Active - Medical 6 85 ~ 264 VAC 1000 W 4 kV 93% - -40°C ~ 85°C (With Derating) 10.00 L x 6.50 W (254.0mm x 165.1mm) 1.60 (40.6mm) cCSAus, CE
CX18M-000000-N-B

CX18M-000000-N-B

CONFIG POWER CHASSIS 1800W 6 SLO

Advanced Energy

7191 480.48
- +

Add To Cart

Inquiry Now

CX18M-000000-N-B

Datasheet

Bulk CoolX™1800 Active - Medical 6 85 ~ 264 VAC 1800 W 4 kV 91% - -40°C ~ 70°C (With Derating) 10.31 L x 5.00 W (262.0mm x 127.0mm) 1.60 (40.6mm) CE
CX18M-000000-N1A

CX18M-000000-N1A

CONFIG DC PWR MOD 1800W FAN COOL

Advanced Energy

7190 480.48
- +

Add To Cart

Inquiry Now

CX18M-000000-N1A

Datasheet

Box CoolX™1800 Active - Medical 6 85 ~ 264 VAC 1800 W 4 kV 93% - -40°C ~ 70°C (With Derating) 10.31 L x 5.00 W (262.0mm x 127.0mm) 1.60 (40.64mm) CE
CX18M-000000-N5A

CX18M-000000-N5A

CONFIG POWER CHASSIS 1800W 6 SLO

Advanced Energy

8568 494.46
- +

Add To Cart

Inquiry Now

CX18M-000000-N5A

Datasheet

Bulk CoolX™1800 Active - Medical 6 85 ~ 264 VAC 1800 W 4 kV 91% - -40°C ~ 70°C (With Derating) 10.31 L x 5.00 W (262.0mm x 127.0mm) 1.60 (40.6mm) CE
XLA-D1

XLA-D1

CONFIGURABLE POWER SUPPLY

Advanced Energy

8161 246.81
- +

Add To Cart

Inquiry Now

XLA-D1

Datasheet

Box Xgen, XL Active - Standard 4 85 ~ 264 VAC 200 W 3 kV 89% Fan Fail, Temperature Alarm -20°C ~ 70°C (With Derating) 10.24 L x 3.50 W (260.0mm x 89.0mm) 1.59 (40.40mm) CE, cURus
CX06S-0000-N1B

CX06S-0000-N1B

CONFIG POWER CHASSIS 600W 4 SLOT

Advanced Energy

7979 270.27
- +

Add To Cart

Inquiry Now

CX06S-0000-N1B

Datasheet

Bulk CoolX™600 NFF Active - Medical 4 85 ~ 264 VAC 600 W 4 kV 94% - -40°C ~ 85°C (With Derating) 8.50 L x 4.50 W (215.9mm x 114.3mm) 1.50 (38.1mm) CE
XMA-00

XMA-00

CONFIG POWER CHASSIS

Advanced Energy

7890 275.22
- +

Add To Cart

Inquiry Now

XMA-00 Box Xgen, XM Active - Medical 4 85 ~ 264 VAC 200 W 4 kV 89% Fan Fail, Temperature Alarm -20°C ~ 70°C (With Derating) 10.24 L x 3.50 W (260.0mm x 89.0mm) 1.59 (40.40mm) CE, cURus
XKB-00

XKB-00

CONFIG POWER CHASSIS 400W 4 SLOT

Advanced Energy

7167 288.98
- +

Add To Cart

Inquiry Now

XKB-00

Datasheet

Box Xgen, XK Active - Standard, Low Noise 4 85 ~ 264 VAC 400 W 3 kV 89% - -20°C ~ 70°C 10.24 L x 3.50 W (260.0mm x 89.0mm) 1.59 (40.40mm) CE, cURus
XKB-02

XKB-02

CONFIGURABLE POWER SUPPLY

Advanced Energy

7294 299.79
- +

Add To Cart

Inquiry Now

XKB-02

Datasheet

Box Xgen, XK Active - Standard, Low Noise 4 85 ~ 264 VAC 400 W 3 kV 89% Fan Fail, Temperature Alarm -20°C ~ 70°C (With Derating) 10.24 L x 3.50 W (260.0mm x 89.0mm) 1.59 (40.40mm) CE, cURus
Total 207 Records«Prev12345...11Next»
Request a Quote
Part Number
Quantity
Contact
Email
Company
Comments
  • Contact Us

    Your Email*
    Message*
  • Home

    Home

    Products

    Products

    Phone

    Phone

    Contact Us

    Contact