Mfr. Part # | Stock | Price | Quantity | Datasheet | Packaging | Series | ProductStatus | Type | NumberofOutputs | Voltage-Input | Voltage-Output1 | Voltage-Output2 | Voltage-Output3 | Voltage-Output4 | Voltage-Output5 | Voltage-Output6 | Current-Output1 | Current-Output2 | Current-Output3 | Current-Output4 | Current-Output5 | Current-Output6 | Power(Watts) | Applications | Voltage-Isolation | Efficiency | OperatingTemperature | Features | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
CX10S-HADBBD-P-A-DK00000AC/DC CNVT 48V 2X12V 48V 2X5V |
7922 | 950.09 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 7 | 85 ~ 264 VAC | 5V | 24V | 5V | 48V | 12V | 12V | 6 A | 3 A | 21 A | 4.17 A | 15 A | 15 A | 965W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-BCAHBB-P-A-DK00000ACDC CNVT 2X12V 5V 2X24V 5V 945W |
8468 | 950.09 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 7 | 85 ~ 264 VAC | 12V | 24V | 5V | 5V | 24V | 12V | 15 A | 8.3 A | 21 A | 6 A | 3 A | 15 A | 945W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-HBADAA-P-A-DK00000ACDC CNVT 2X5V 48V 5V 2X12V 795W |
7862 | 950.09 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 7 | 85 ~ 264 VAC | 5V | 24V | 12V | 5V | 48V | 5V | 6 A | 3 A | 15 A | 21 A | 4.17 A | 21 A | 795W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-ABDGBD-P-A-DK00000AC/DC CNVT 48V 12V 2X24V 12V 48V |
7195 | 950.09 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 7 | 85 ~ 264 VAC | 5V | 12V | 48V | 24V | 24V | 12V | 21 A | 15 A | 4.17 A | 3 A | 3 A | 15 A | 985W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-HCBAAD-P-A-DK00000AC/DC CNVT 48V 2X5V 12V 2X24V |
7676 | 950.09 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 7 | 85 ~ 264 VAC | 5V | 24V | 24V | 12V | 5V | 5V | 6 A | 3 A | 8.3 A | 15 A | 21 A | 21 A | 890W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-HADCBA-P-A-DK00000AC/DC CNVT 5V 12V 24V 48V 2X5V |
8081 | 950.09 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 7 | 85 ~ 264 VAC | 5V | 24V | 5V | 48V | 24V | 12V | 6 A | 3 A | 21 A | 4.17 A | 8.3 A | 15 A | 890W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-ABCBAG-P-A-DK00000AC/DC CNVT 2X24V 5V 2X12V 24V |
8668 | 950.09 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 7 | 85 ~ 264 VAC | 5V | 12V | 24V | 12V | 5V | 24V | 21 A | 15 A | 8.3 A | 15 A | 21 A | 3 A | 890W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-HDCDAD-P-A-DK00000AC/DC CNVT 48V 5V 48V 24V 2X48V |
8384 | 950.09 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 7 | 85 ~ 264 VAC | 5V | 24V | 48V | 24V | 48V | 5V | 6 A | 3 A | 4.17 A | 8.3 A | 4.17 A | 21 A | 1000W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-ADCGDB-P-A-DK00000AC/DC CNVT 12V 48V 2X24V 48V 24V |
7203 | 950.09 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 7 | 85 ~ 264 VAC | 5V | 48V | 24V | 24V | 24V | 48V | 21 A | 4.17 A | 8.3 A | 3 A | 3 A | 4.17 A | 1000W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-ABDHAC-P-A-DK00000AC/DC CNVT 24V 2X5V 24V 12V 48V |
8153 | 950.09 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 7 | 85 ~ 264 VAC | 5V | 12V | 48V | 5V | 24V | 5V | 21 A | 15 A | 4.17 A | 6 A | 3 A | 21 A | 890W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-HADDBB-P-A-DK00000AC/DC CNVT 2X12V 2X48V 2X5V 965W |
8443 | 950.09 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 7 | 85 ~ 264 VAC | 5V | 24V | 5V | 48V | 48V | 12V | 6 A | 3 A | 21 A | 4.17 A | 4.17 A | 15 A | 965W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-HCCCBA-P-A-DK00000AC/DC CNVT 5V 12V 4X24V 985W |
7043 | 950.09 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 7 | 85 ~ 264 VAC | 5V | 24V | 24V | 24V | 24V | 12V | 6 A | 3 A | 8.3 A | 8.3 A | 8.3 A | 15 A | 985W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-HDABBB-P-A-DK00000AC/DC CNVT 3X12V 5V 2X48V 945W |
7176 | 950.09 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 7 | 85 ~ 264 VAC | 5V | 24V | 48V | 5V | 12V | 12V | 6 A | 3 A | 4.17 A | 21 A | 15 A | 15 A | 945W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-HACDDD-P-A-DK00000AC/DC CNVT 3X48V 24V 2X5V 1000W |
8040 | 950.09 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 7 | 85 ~ 264 VAC | 5V | 24V | 5V | 24V | 48V | 48V | 6 A | 3 A | 21 A | 8.3 A | 4.17 A | 4.17 A | 1000W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-HCAADD-P-A-DK00000AC/DC CNVT 2X48V 2X5V 2X24V 910W |
7959 | 950.09 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 7 | 85 ~ 264 VAC | 5V | 24V | 24V | 5V | 5V | 48V | 6 A | 3 A | 8.3 A | 21 A | 21 A | 4.17 A | 910W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-HCBDBB-P-A-DK00000AC/DC CNVT 2X12V 48V 12V 2X24V |
6964 | 950.09 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 7 | 85 ~ 264 VAC | 5V | 24V | 24V | 12V | 48V | 12V | 6 A | 3 A | 8.3 A | 15 A | 4.17 A | 15 A | 1000W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-HDACCB-P-A-DK00000AC/DC CNVT 12V 2X24V 5V 2X48V |
8229 | 950.09 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 7 | 85 ~ 264 VAC | 5V | 24V | 48V | 5V | 24V | 24V | 6 A | 3 A | 4.17 A | 21 A | 8.3 A | 8.3 A | 985W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-HDACBB-P-A-DK00000AC/DC CNVT 2X12V 24V 5V 2X48V |
7542 | 950.09 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 7 | 85 ~ 264 VAC | 5V | 24V | 48V | 5V | 24V | 12V | 6 A | 3 A | 4.17 A | 21 A | 8.3 A | 15 A | 965W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-AACGCB-P-A-DK00000AC/DC CNVT 12V 3X24V 5V 24V 910W |
8311 | 950.09 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 7 | 85 ~ 264 VAC | 5V | 5V | 24V | 24V | 24V | 24V | 21 A | 21 A | 8.3 A | 3 A | 3 A | 8.3 A | 910W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-ABBDCG-P-A-DK00000AC/DC CNVT 3X24V 48V 2X12V 985W |
8216 | 950.09 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 7 | 85 ~ 264 VAC | 5V | 12V | 12V | 48V | 24V | 24V | 21 A | 15 A | 15 A | 4.17 A | 8.3 A | 3 A | 985W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |