Mfr. Part # | Stock | Price | Quantity | Datasheet | Packaging | Series | ProductStatus | Type | NumberofOutputs | Voltage-Input | Voltage-Output1 | Voltage-Output2 | Voltage-Output3 | Voltage-Output4 | Voltage-Output5 | Voltage-Output6 | Current-Output1 | Current-Output2 | Current-Output3 | Current-Output4 | Current-Output5 | Current-Output6 | Power(Watts) | Applications | Voltage-Isolation | Efficiency | OperatingTemperature | Features | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
CX10S-ABHBAC-P-A-DK00000AC/DC CNVT 24V 5V 12V 5V 12V 24V |
8514 | 950.09 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 7 | 85 ~ 264 VAC | 5V | 12V | 5V | 24V | 12V | 5V | 21 A | 15 A | 6 A | 3 A | 15 A | 21 A | 870W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-HBCCBC-P-A-DK00000AC/DC CNVT 24V 12V 2X24V 2X12V |
8549 | 950.09 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 7 | 85 ~ 264 VAC | 5V | 24V | 12V | 24V | 24V | 12V | 6 A | 3 A | 15 A | 8.3 A | 8.3 A | 15 A | 1000W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-HDBCBA-P-A-DK00000AC/DC CNVT 5V 12V 24V 12V 2X48V |
8494 | 950.09 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 7 | 85 ~ 264 VAC | 5V | 24V | 48V | 12V | 24V | 12V | 6 A | 3 A | 4.17 A | 15 A | 8.3 A | 15 A | 965W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-AGDACC-P-A-DK00000AC/DC CNVT 2X24V 5V 48V 3X24V |
8109 | 950.09 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 7 | 85 ~ 264 VAC | 5V | 24V | 24V | 48V | 5V | 24V | 21 A | 3 A | 3 A | 4.17 A | 21 A | 8.3 A | 930W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-AAHBAB-P-A-DK00000AC/DC CNVT 12V 5V 12V 2X5V 24V |
8351 | 950.09 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 7 | 85 ~ 264 VAC | 5V | 5V | 5V | 24V | 12V | 5V | 21 A | 21 A | 6 A | 3 A | 15 A | 21 A | 775W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-ABCCHD-P-A-DK00000AC/DC CNVT 48V 5V 2X24V 12V 24V |
6718 | 950.09 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 7 | 85 ~ 264 VAC | 5V | 12V | 24V | 24V | 5V | 24V | 21 A | 15 A | 8.3 A | 8.3 A | 6 A | 3 A | 985W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-ABCCHB-P-A-DK00000AC/DC CNVT 12V 5V 2X24V 12V 24V |
7825 | 950.09 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 7 | 85 ~ 264 VAC | 5V | 12V | 24V | 24V | 5V | 24V | 21 A | 15 A | 8.3 A | 8.3 A | 6 A | 3 A | 965W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-AACAGB-P-A-DK00000AC/DC CNVT 12V 2X24V 2X5V 24V |
8259 | 950.09 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 7 | 85 ~ 264 VAC | 5V | 5V | 24V | 5V | 24V | 24V | 21 A | 21 A | 8.3 A | 21 A | 3 A | 3 A | 815W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-ABDHCD-P-A-DK00000ACDC CNVT 48V 24V 5V 24V 12V 48V |
7106 | 950.09 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 7 | 85 ~ 264 VAC | 5V | 12V | 48V | 5V | 24V | 24V | 21 A | 15 A | 4.17 A | 6 A | 3 A | 8.3 A | 985W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-ADGCAC-P-A-DK00000AC/DC CNVT 24V 5V 2X24V 48V 24V |
8042 | 950.09 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 7 | 85 ~ 264 VAC | 5V | 48V | 24V | 24V | 24V | 5V | 21 A | 4.17 A | 3 A | 3 A | 8.3 A | 21 A | 930W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-ADCHDC-P-A-DK00000ACDC CNVT 24V 48V 5V 24V 48V 24V |
8178 | 950.09 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 7 | 85 ~ 264 VAC | 5V | 48V | 24V | 5V | 24V | 48V | 21 A | 4.17 A | 8.3 A | 6 A | 3 A | 4.17 A | 1000W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-ADCHCD-P-A-DK00000ACDC CNVT 48V 24V 5V 24V 48V 24V |
8054 | 950.09 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 7 | 85 ~ 264 VAC | 5V | 48V | 24V | 5V | 24V | 24V | 21 A | 4.17 A | 8.3 A | 6 A | 3 A | 8.3 A | 1000W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-AAACGD-P-A-DK00000AC/DC CNVT 48V 3X24V 2X5V 835W |
7025 | 950.09 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 7 | 85 ~ 264 VAC | 5V | 5V | 5V | 24V | 24V | 24V | 21 A | 21 A | 21 A | 8.3 A | 3 A | 3 A | 835W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-ACHCCA-P-A-DK00000ACDC CNVT 5V 2X24V 5V 2X24V 910W |
8250 | 950.09 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 7 | 85 ~ 264 VAC | 5V | 24V | 5V | 24V | 24V | 24V | 21 A | 8.3 A | 6 A | 3 A | 8.3 A | 8.3 A | 910W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-ADGCDA-P-A-DK00000AC/DC CNVT 5V 48V 2X24V 48V 24V |
7463 | 950.09 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 7 | 85 ~ 264 VAC | 5V | 48V | 24V | 24V | 24V | 48V | 21 A | 4.17 A | 3 A | 3 A | 8.3 A | 4.17 A | 930W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-ACCDGD-P-A-DK00000AC/DC CNVT 48V 2X24V 48V 2X24V |
7854 | 950.09 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 7 | 85 ~ 264 VAC | 5V | 24V | 24V | 48V | 24V | 24V | 21 A | 8.3 A | 8.3 A | 4.17 A | 3 A | 3 A | 1000W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-AAACHD-P-A-DK00000ACDC CNVT 48V 5V 2X24V 2X5V 815W |
8169 | 950.09 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 7 | 85 ~ 264 VAC | 5V | 5V | 5V | 24V | 5V | 24V | 21 A | 21 A | 21 A | 8.3 A | 6 A | 3 A | 815W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-ABCCCH-P-A-DK00000AC/DC CNVT 5V 3X24V 12V 24V 985W |
8571 | 950.09 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 7 | 85 ~ 264 VAC | 5V | 12V | 24V | 24V | 24V | 5V | 21 A | 15 A | 8.3 A | 8.3 A | 8.3 A | 6 A | 985W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-ADBDHA-P-A-DK00000AC/DC CNVT 2X5V 24V 2X48V 12V |
7636 | 950.09 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 7 | 85 ~ 264 VAC | 5V | 48V | 12V | 48V | 5V | 24V | 21 A | 4.17 A | 15 A | 4.17 A | 6 A | 3 A | 890W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-ABHDBD-P-A-DK00000ACDC CNV 48V 12V 48V 5V 12V 24V |
7756 | 950.09 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 7 | 85 ~ 264 VAC | 5V | 12V | 5V | 24V | 48V | 12V | 21 A | 15 A | 6 A | 3 A | 4.17 A | 15 A | 965W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |