Mfr. Part # | Stock | Price | Quantity | Datasheet | Packaging | Series | ProductStatus | Type | NumberofOutputs | Voltage-Input | Voltage-Output1 | Voltage-Output2 | Voltage-Output3 | Voltage-Output4 | Voltage-Output5 | Voltage-Output6 | Current-Output1 | Current-Output2 | Current-Output3 | Current-Output4 | Current-Output5 | Current-Output6 | Power(Watts) | Applications | Voltage-Isolation | Efficiency | OperatingTemperature | Features | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
CX10S-ADACHB-P-A-DK00000AC/DC CNVT 12V 5V 2X24V 48V 5V |
8024 | 950.09 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 7 | 85 ~ 264 VAC | 5V | 48V | 5V | 24V | 5V | 24V | 21 A | 4.17 A | 21 A | 8.3 A | 6 A | 3 A | 890W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-ABGCAA-P-A-DK00000AC/DC CNVT 2X5V 2X24V 12V 24V |
8049 | 950.09 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 7 | 85 ~ 264 VAC | 5V | 12V | 24V | 24V | 24V | 5V | 21 A | 15 A | 3 A | 3 A | 8.3 A | 21 A | 815W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-BDHAAC-P-A-DK00000AC/DC CNVT 24V 3X5V 48V 24V 890W |
7460 | 950.09 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 7 | 85 ~ 264 VAC | 12V | 48V | 5V | 24V | 5V | 5V | 15 A | 4.17 A | 6 A | 3 A | 21 A | 21 A | 890W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-ABGCCB-P-A-DK00000ACDC CNVT 12V 3X24V 12V 24V 985W |
8441 | 950.09 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 7 | 85 ~ 264 VAC | 5V | 12V | 24V | 24V | 24V | 24V | 21 A | 15 A | 3 A | 3 A | 8.3 A | 8.3 A | 985W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-ACHDBD-P-A-DK00000AC/DC CNVT 48V 12V 48V 5V 2X24V |
7116 | 950.09 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 7 | 85 ~ 264 VAC | 5V | 24V | 5V | 24V | 48V | 12V | 21 A | 8.3 A | 6 A | 3 A | 4.17 A | 15 A | 985W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-AGACAD-P-A-DK00000AC/DC CNVT 48V 5V 24V 5V 3X24V |
7542 | 950.09 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 7 | 85 ~ 264 VAC | 5V | 24V | 24V | 5V | 24V | 5V | 21 A | 3 A | 3 A | 21 A | 8.3 A | 21 A | 835W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-AAADHB-P-A-DK00000AC/DC CNVT 12V 5V 24V 48V 2X5V |
7651 | 950.09 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 7 | 85 ~ 264 VAC | 5V | 5V | 5V | 48V | 5V | 24V | 21 A | 21 A | 21 A | 4.17 A | 6 A | 3 A | 795W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-ADAADH-P-A-DK00000AC/DC CNVT 5V 24V 48V 5V 48V 5V |
6917 | 950.09 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 7 | 85 ~ 264 VAC | 5V | 48V | 5V | 5V | 48V | 5V | 21 A | 4.17 A | 21 A | 21 A | 4.17 A | 6 A | 815W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-ADBGAC-P-A-DK00000AC/DC CNVT 24V 5V 2X24V 48V 12V |
6920 | 950.09 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 7 | 85 ~ 264 VAC | 5V | 48V | 12V | 24V | 24V | 5V | 21 A | 4.17 A | 15 A | 3 A | 3 A | 21 A | 910W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-AGACCD-P-A-DK00000AC/DC CNVT 48V 2X24V 5V 3X24V |
7137 | 950.09 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 7 | 85 ~ 264 VAC | 5V | 24V | 24V | 5V | 24V | 24V | 21 A | 3 A | 3 A | 21 A | 8.3 A | 8.3 A | 930W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-ABBABH-P-A-DK00000AC/DC CNVT 5V 24V 12V 5V 2X12V |
8214 | 950.09 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 7 | 85 ~ 264 VAC | 5V | 12V | 12V | 5V | 12V | 5V | 21 A | 15 A | 15 A | 21 A | 15 A | 6 A | 850W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-AADDDG-P-A-DK00000AC/DC CNVT 2X24V 2X48V 5V 48V |
6945 | 950.09 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 7 | 85 ~ 264 VAC | 5V | 5V | 48V | 48V | 48V | 24V | 21 A | 21 A | 4.17 A | 4.17 A | 4.17 A | 3 A | 930W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-AAAGBD-P-A-DK00000AC/DC CNVT 48V 12V 2X24V 2X5V |
7373 | 950.09 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 7 | 85 ~ 264 VAC | 5V | 5V | 5V | 24V | 24V | 12V | 21 A | 21 A | 21 A | 3 A | 3 A | 15 A | 815W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-AAAGAD-P-A-DK00000ACDC CNVT 48V 5V 2X24V 2X5V 740W |
7316 | 950.09 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 7 | 85 ~ 264 VAC | 5V | 5V | 5V | 24V | 24V | 5V | 21 A | 21 A | 21 A | 3 A | 3 A | 21 A | 740W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-ABBAHA-P-A-DK00000ACDC CNVT 2X5V 24V 5V 2X12V 775W |
7749 | 950.09 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 7 | 85 ~ 264 VAC | 5V | 12V | 12V | 5V | 5V | 24V | 21 A | 15 A | 15 A | 21 A | 6 A | 3 A | 775W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-AGADBA-P-A-DK00000AC/DC CNVT 5V 12V 48V 5V 3X24V |
8087 | 950.09 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 7 | 85 ~ 264 VAC | 5V | 24V | 24V | 5V | 48V | 12V | 21 A | 3 A | 3 A | 21 A | 4.17 A | 15 A | 815W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-AAHCCB-P-A-DK00000AC/DC CNVT 12V 2X24V 2X5V 24V |
8474 | 950.09 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 7 | 85 ~ 264 VAC | 5V | 5V | 5V | 24V | 24V | 24V | 21 A | 21 A | 6 A | 3 A | 8.3 A | 8.3 A | 890W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-AHBBCA-P-A-DK00000ACDC CNVT 5V 24V 2X12V 5V 24V 5V |
7398 | 950.09 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 7 | 85 ~ 264 VAC | 5V | 5V | 24V | 12V | 12V | 24V | 21 A | 6 A | 3 A | 15 A | 15 A | 8.3 A | 870W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-ABCGDD-P-A-DK00000AC/DC CNVT 2X48V 2X24V 12V 24V |
6854 | 950.09 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 7 | 85 ~ 264 VAC | 5V | 12V | 24V | 24V | 24V | 48V | 21 A | 15 A | 8.3 A | 3 A | 3 A | 4.17 A | 1000W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-ABBBBH-P-A-DK00000AC/DC CNVT 5V 24V 4X12V 925W |
7366 | 950.09 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 7 | 85 ~ 264 VAC | 5V | 12V | 12V | 12V | 12V | 5V | 21 A | 15 A | 15 A | 15 A | 15 A | 6 A | 925W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
Tel