Mfr. Part # | Stock | Price | Quantity | Datasheet | Packaging | Series | ProductStatus | Type | NumberofOutputs | Voltage-Input | Voltage-Output1 | Voltage-Output2 | Voltage-Output3 | Voltage-Output4 | Voltage-Output5 | Voltage-Output6 | Current-Output1 | Current-Output2 | Current-Output3 | Current-Output4 | Current-Output5 | Current-Output6 | Power(Watts) | Applications | Voltage-Isolation | Efficiency | OperatingTemperature | Features | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
CX10S-BDCHGB-P-A-DK00000AC/DC CNVT 12V 2X24V 5V 48V 24V |
7422 | 960.01 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 8 | 85 ~ 264 VAC | 12V | 48V | 24V | 5V | 24V | 24V | 15 A | 4.17 A | 8.3 A | 6 A | 3 A | 3 A | 980W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-AHDBGA-P-A-DK00000ACDC CNV 5V 2X24V 12V 5V 24V 48V |
8213 | 960.01 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 8 | 85 ~ 264 VAC | 5V | 5V | 24V | 48V | 12V | 24V | 21 A | 6 A | 3 A | 4.17 A | 15 A | 3 A | 810W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-BDGBCG-P-A-DK00000AC/DC CNVT 3X24V 12V 48V 24V |
8091 | 960.01 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 8 | 85 ~ 264 VAC | 12V | 48V | 24V | 24V | 12V | 24V | 15 A | 4.17 A | 3 A | 3 A | 15 A | 8.3 A | 1000W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-BCHDBG-P-A-DK00000AC/DC CNVT 2X24V 12V 48V 24V 5V |
7102 | 960.01 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 8 | 85 ~ 264 VAC | 12V | 24V | 5V | 24V | 48V | 12V | 15 A | 8.3 A | 6 A | 3 A | 4.17 A | 15 A | 980W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-BDHGDC-P-A-DK00000AC/DC CNVT 24V 48V 2X24V 48V 5V |
8526 | 960.01 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 8 | 85 ~ 264 VAC | 12V | 48V | 5V | 24V | 24V | 24V | 15 A | 4.17 A | 6 A | 3 A | 3 A | 3 A | 1000W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-BGABCG-P-A-DK00000AC/DC CNVT 3X24V 12V 2X24V 5V |
8613 | 960.01 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 8 | 85 ~ 264 VAC | 12V | 24V | 24V | 5V | 12V | 24V | 15 A | 3 A | 3 A | 21 A | 15 A | 8.3 A | 905W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-BAAGHA-P-A-DK00000ACDC CNVT 2X5V 2X24V 5V 24V 715W |
6775 | 960.01 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 8 | 85 ~ 264 VAC | 12V | 5V | 5V | 24V | 24V | 5V | 15 A | 21 A | 21 A | 3 A | 3 A | 6 A | 715W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-BBHBBH-P-A-DK00000AC/DC CNVT 5V 24V 3X12V 5V 920W |
7322 | 960.01 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 8 | 85 ~ 264 VAC | 12V | 12V | 5V | 24V | 12V | 12V | 15 A | 15 A | 6 A | 3 A | 15 A | 15 A | 920W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-BDGBGD-P-A-DK00000AC/DC CNVT 48V 2X24V 12V 48V 24V |
7575 | 960.01 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 8 | 85 ~ 264 VAC | 12V | 48V | 24V | 24V | 12V | 24V | 15 A | 4.17 A | 3 A | 3 A | 15 A | 3 A | 1000W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-CCGCGD-P-A-DK00000AC/DC CONVERTER 48V 5X24V 1000W |
7197 | 960.01 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 8 | 85 ~ 264 VAC | 24V | 24V | 24V | 24V | 24V | 24V | 8.3 A | 8.3 A | 3 A | 3 A | 8.3 A | 3 A | 1000W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-BGBGBC-P-A-DK00000ACDC CNVT 24V 12V 4X24V 12V 980W |
8549 | 960.01 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 8 | 85 ~ 264 VAC | 12V | 24V | 24V | 12V | 24V | 24V | 15 A | 3 A | 3 A | 15 A | 3 A | 3 A | 980W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-BGBGDA-P-A-DK00000AC/DC CNVT 5V 48V 4X24V 12V 905W |
8441 | 960.01 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 8 | 85 ~ 264 VAC | 12V | 24V | 24V | 12V | 24V | 24V | 15 A | 3 A | 3 A | 15 A | 3 A | 3 A | 905W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-BDGBHD-P-A-DK00000ACDC CNVT 48V 5V 24V 12V 48V 24V |
7846 | 960.01 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 8 | 85 ~ 264 VAC | 12V | 48V | 24V | 24V | 12V | 5V | 15 A | 4.17 A | 3 A | 3 A | 15 A | 6 A | 980W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-CDGGDA-P-A-DK00000AC/DC CNVT 5V 48V 2X24V 48V 24V |
7194 | 960.01 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 8 | 85 ~ 264 VAC | 24V | 48V | 24V | 24V | 24V | 24V | 8.3 A | 4.17 A | 3 A | 3 A | 3 A | 3 A | 945W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-CGADGC-P-A-DK00000AC/DC CNVT 3X24V 48V 2X24V 5V |
7721 | 960.01 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 8 | 85 ~ 264 VAC | 24V | 24V | 24V | 5V | 48V | 24V | 8.3 A | 3 A | 3 A | 21 A | 4.17 A | 3 A | 945W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-CGCAAG-P-A-DK00000AC/DC CNVT 2X24V 2X5V 3X24V 850W |
8312 | 960.01 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 8 | 85 ~ 264 VAC | 24V | 24V | 24V | 24V | 5V | 5V | 8.3 A | 3 A | 3 A | 8.3 A | 21 A | 21 A | 850W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-BGABBG-P-A-DK00000AC/DC CNVT 2X24V 2X12V 2X24V 5V |
7683 | 960.01 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 8 | 85 ~ 264 VAC | 12V | 24V | 24V | 5V | 12V | 12V | 15 A | 3 A | 3 A | 21 A | 15 A | 15 A | 885W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-CBHGBA-P-A-DK00000AC/DC CNVT 5V 12V 2X24V 12V 5V |
6767 | 960.01 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 8 | 85 ~ 264 VAC | 24V | 12V | 5V | 24V | 24V | 24V | 8.3 A | 15 A | 6 A | 3 A | 3 A | 3 A | 885W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-BGGDDD-P-A-DK00000AC/DC CNVT 3X48V 4X24V 1000W |
8075 | 960.01 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 8 | 85 ~ 264 VAC | 12V | 24V | 24V | 24V | 24V | 48V | 15 A | 3 A | 3 A | 3 A | 3 A | 4.17 A | 1000W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-BDHHBC-P-A-DK00000AC/DC CNVT 24V 12V 5V 24V 48V 5V |
7362 | 960.01 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 8 | 85 ~ 264 VAC | 12V | 48V | 5V | 24V | 5V | 24V | 15 A | 4.17 A | 6 A | 3 A | 6 A | 3 A | 960W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |