Mfr. Part # | Stock | Price | Quantity | Datasheet | Packaging | Series | ProductStatus | Type | NumberofOutputs | Voltage-Input | Voltage-Output1 | Voltage-Output2 | Voltage-Output3 | Voltage-Output4 | Voltage-Output5 | Voltage-Output6 | Current-Output1 | Current-Output2 | Current-Output3 | Current-Output4 | Current-Output5 | Current-Output6 | Power(Watts) | Applications | Voltage-Isolation | Efficiency | OperatingTemperature | Features | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
CX10S-BCGDHB-P-A-DK00000AC/DC CNVT 12V 5V 24V 48V 2X24V |
7519 | 960.01 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 8 | 85 ~ 264 VAC | 12V | 24V | 24V | 24V | 48V | 5V | 15 A | 8.3 A | 3 A | 3 A | 4.17 A | 6 A | 980W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-CGDGCD-P-A-DK00000AC/DC CNVT 48V 5X24V 48V 1000W |
7642 | 960.01 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 8 | 85 ~ 264 VAC | 24V | 24V | 24V | 48V | 24V | 24V | 8.3 A | 3 A | 3 A | 4.17 A | 3 A | 3 A | 1000W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-CAGCHA-P-A-DK00000ACDC CNVT 2X5V 2X24V 5V 24V 830W |
6938 | 960.01 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 8 | 85 ~ 264 VAC | 24V | 5V | 24V | 24V | 24V | 5V | 8.3 A | 21 A | 3 A | 3 A | 8.3 A | 6 A | 830W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-BBGCHC-P-A-DK00000AC/DC CNVT 24V 5V 2X24V 12V 24V |
7053 | 960.01 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 8 | 85 ~ 264 VAC | 12V | 12V | 24V | 24V | 24V | 5V | 15 A | 15 A | 3 A | 3 A | 8.3 A | 6 A | 980W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-AHGAAD-P-A-DK00000AC/DC CNVT 48V 2X5V 24V 5V 2X24V |
7737 | 960.01 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 8 | 85 ~ 264 VAC | 5V | 5V | 24V | 24V | 24V | 5V | 21 A | 6 A | 3 A | 3 A | 3 A | 21 A | 735W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-CBBGGC-P-A-DK00000AC/DC CNVT 4X24V 12V 24V 1000W |
6816 | 960.01 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 8 | 85 ~ 264 VAC | 24V | 12V | 12V | 24V | 24V | 24V | 8.3 A | 15 A | 15 A | 3 A | 3 A | 3 A | 1000W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-CBGGDA-P-A-DK00000AC/DC CNVT 5V 48V 2X24V 12V 24V |
8156 | 960.01 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 8 | 85 ~ 264 VAC | 24V | 12V | 24V | 24V | 24V | 24V | 8.3 A | 15 A | 3 A | 3 A | 3 A | 3 A | 925W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-BHCCHA-P-A-DK00000AC/DC CNVT 2X5V 2X24V 5V 2X24V |
7622 | 960.01 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 8 | 85 ~ 264 VAC | 12V | 5V | 24V | 24V | 24V | 5V | 15 A | 6 A | 3 A | 8.3 A | 8.3 A | 6 A | 885W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-BGDDGA-P-A-DK00000ACDC CNVT 5V 2X24V 48V 2X24V 48V |
6928 | 960.01 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 8 | 85 ~ 264 VAC | 12V | 24V | 24V | 48V | 48V | 24V | 15 A | 3 A | 3 A | 4.17 A | 4.17 A | 3 A | 925W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-BDGHBA-P-A-DK00000ACDC CNVT 5V 12V 5V 24V 48V 24V |
7064 | 960.01 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 8 | 85 ~ 264 VAC | 12V | 48V | 24V | 24V | 5V | 24V | 15 A | 4.17 A | 3 A | 3 A | 6 A | 3 A | 885W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-AHHACA-P-A-DK00000ACDC CNVT 5V 24V 3X5V 2X24V 715W |
7823 | 960.01 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 8 | 85 ~ 264 VAC | 5V | 5V | 24V | 5V | 24V | 5V | 21 A | 6 A | 3 A | 6 A | 3 A | 21 A | 715W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-CBBGDG-P-A-DK00000AC/DC CNVT 2X24V 48V 24V 12V 24V |
7209 | 960.01 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 8 | 85 ~ 264 VAC | 24V | 12V | 12V | 24V | 24V | 48V | 8.3 A | 15 A | 15 A | 3 A | 3 A | 4.17 A | 1000W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-CGBABG-P-A-DK00000ACDC CNVT 2X24V 12V 5V 2X24V 12V |
7867 | 960.01 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 8 | 85 ~ 264 VAC | 24V | 24V | 24V | 12V | 5V | 12V | 8.3 A | 3 A | 3 A | 15 A | 21 A | 15 A | 905W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-CDAHCH-P-A-DK00000AC/DC CNVT 5V 2X24V 5V 48V 24V |
6994 | 960.01 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 8 | 85 ~ 264 VAC | 24V | 48V | 5V | 5V | 24V | 24V | 8.3 A | 4.17 A | 21 A | 6 A | 3 A | 8.3 A | 905W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-BGDDCH-P-A-DK00000ACDC CNVT 5V 2X24V 48V 2X24V 48V |
8656 | 960.01 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 8 | 85 ~ 264 VAC | 12V | 24V | 24V | 48V | 48V | 24V | 15 A | 3 A | 3 A | 4.17 A | 4.17 A | 8.3 A | 1000W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-BBCHHC-P-A-DK00000AC/DC CNVT 24V 5V 24V 5V 12V 24V |
7586 | 960.01 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 8 | 85 ~ 264 VAC | 12V | 12V | 24V | 5V | 24V | 5V | 15 A | 15 A | 8.3 A | 6 A | 3 A | 6 A | 960W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-CDAHCG-P-A-DK00000AC/DC CNVT 3X24V 5V 48V 24V 925W |
7249 | 960.01 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 8 | 85 ~ 264 VAC | 24V | 48V | 5V | 5V | 24V | 24V | 8.3 A | 4.17 A | 21 A | 6 A | 3 A | 8.3 A | 925W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-CBBGHA-P-A-DK00000AC/DC CNVT 2X5V 2X24V 12V 24V |
6778 | 960.01 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 8 | 85 ~ 264 VAC | 24V | 12V | 12V | 24V | 24V | 5V | 8.3 A | 15 A | 15 A | 3 A | 3 A | 6 A | 885W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-BDGHCB-P-A-DK00000ACDC CNVT 12V 24V 5V 24V 48V 24V |
7428 | 960.01 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 8 | 85 ~ 264 VAC | 12V | 48V | 24V | 24V | 5V | 24V | 15 A | 4.17 A | 3 A | 3 A | 6 A | 3 A | 980W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-CBGHBB-P-A-DK00000AC/DC CNVT 2X12V 5V 24V 12V 24V |
8096 | 960.01 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 8 | 85 ~ 264 VAC | 24V | 12V | 24V | 24V | 5V | 24V | 8.3 A | 15 A | 3 A | 3 A | 6 A | 3 A | 960W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |