Mfr. Part # | Stock | Price | Quantity | Datasheet | Packaging | Series | ProductStatus | Type | NumberofOutputs | Voltage-Input | Voltage-Output1 | Voltage-Output2 | Voltage-Output3 | Voltage-Output4 | Voltage-Output5 | Voltage-Output6 | Current-Output1 | Current-Output2 | Current-Output3 | Current-Output4 | Current-Output5 | Current-Output6 | Power(Watts) | Applications | Voltage-Isolation | Efficiency | OperatingTemperature | Features | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
CX10S-BBHHAC-P-A-DK00000AC/DC CNVT 24V 2X5V 24V 12V 5V |
7315 | 960.01 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 8 | 85 ~ 264 VAC | 12V | 12V | 5V | 24V | 5V | 24V | 15 A | 15 A | 6 A | 3 A | 6 A | 3 A | 865W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-BGAGCD-P-A-DK00000AC/DC CNVT 48V 5X24V 5V 925W |
7715 | 960.01 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 8 | 85 ~ 264 VAC | 12V | 24V | 24V | 5V | 24V | 24V | 15 A | 3 A | 3 A | 21 A | 3 A | 3 A | 925W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-BGDDAH-P-A-DK00000ACDC CNV 5V 24V 5V 48V 2X24V 48V |
7918 | 960.01 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 8 | 85 ~ 264 VAC | 12V | 24V | 24V | 48V | 48V | 5V | 15 A | 3 A | 3 A | 4.17 A | 4.17 A | 21 A | 905W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-CDAGHB-P-A-DK00000AC/DC CNVT 12V 5V 2X24V 48V 24V |
7731 | 960.01 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 8 | 85 ~ 264 VAC | 24V | 48V | 5V | 24V | 24V | 5V | 8.3 A | 4.17 A | 21 A | 3 A | 3 A | 6 A | 905W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-BBHGDC-P-A-DK00000AC/DC CNVT 24V 48V 2X24V 12V 5V |
8190 | 960.01 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 8 | 85 ~ 264 VAC | 12V | 12V | 5V | 24V | 24V | 24V | 15 A | 15 A | 6 A | 3 A | 3 A | 3 A | 980W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-BDGHCA-P-A-DK00000AC/DC CNVT 5V 24V 5V 24V 48V 24V |
7045 | 960.01 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 8 | 85 ~ 264 VAC | 12V | 48V | 24V | 24V | 5V | 24V | 15 A | 4.17 A | 3 A | 3 A | 6 A | 3 A | 905W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-BBHGDB-P-A-DK00000AC/DC CNVT 12V 48V 2X24V 12V 5V |
7944 | 960.01 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 8 | 85 ~ 264 VAC | 12V | 12V | 5V | 24V | 24V | 24V | 15 A | 15 A | 6 A | 3 A | 3 A | 3 A | 960W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-CBGHDA-P-A-DK00000AC/DC CNVT 5V 48V 5V 24V 12V 24V |
7874 | 960.01 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 8 | 85 ~ 264 VAC | 24V | 12V | 24V | 24V | 5V | 24V | 8.3 A | 15 A | 3 A | 3 A | 6 A | 3 A | 905W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-BHCDBH-P-A-DK00000ACDC CNV 5V 24V 12V 48V 5V 2X24V |
6823 | 960.01 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 8 | 85 ~ 264 VAC | 12V | 5V | 24V | 24V | 48V | 12V | 15 A | 6 A | 3 A | 8.3 A | 4.17 A | 15 A | 960W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-CGDGDB-P-A-DK00000AC/DC CNVT 12V 48V 4X24V 48V |
7783 | 960.01 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 8 | 85 ~ 264 VAC | 24V | 24V | 24V | 48V | 24V | 24V | 8.3 A | 3 A | 3 A | 4.17 A | 3 A | 3 A | 1000W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-CDCBHG-P-A-DK00000AC/DC CNVT 2X24V 5V 24V 48V 12V |
7732 | 960.01 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 8 | 85 ~ 264 VAC | 24V | 48V | 24V | 12V | 5V | 24V | 8.3 A | 4.17 A | 8.3 A | 15 A | 6 A | 3 A | 1000W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-CAHHDC-P-A-DK00000AC/DC CNVT 24V 48V 5V 24V 2X5V |
8601 | 960.01 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 8 | 85 ~ 264 VAC | 24V | 5V | 5V | 24V | 5V | 24V | 8.3 A | 21 A | 6 A | 3 A | 6 A | 3 A | 905W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-BGDDHC-P-A-DK00000ACDC CN 24V 5V 24V 48V 2X24V 48V |
7096 | 960.01 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 8 | 85 ~ 264 VAC | 12V | 24V | 24V | 48V | 48V | 5V | 15 A | 3 A | 3 A | 4.17 A | 4.17 A | 6 A | 1000W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-BGCBBG-P-A-DK00000ACDC CNVT 2X24V 2X12V 3X24V 980W |
6964 | 960.01 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 8 | 85 ~ 264 VAC | 12V | 24V | 24V | 24V | 12V | 12V | 15 A | 3 A | 3 A | 8.3 A | 15 A | 15 A | 980W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-CDAHGB-P-A-DK00000AC/DC CNVT 12V 2X24V 5V 48V 24V |
6821 | 960.01 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 8 | 85 ~ 264 VAC | 24V | 48V | 5V | 5V | 24V | 24V | 8.3 A | 4.17 A | 21 A | 6 A | 3 A | 3 A | 905W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-CBGHBA-P-A-DK00000ACDC CNVT 5V 12V 5V 24V 12V 24V |
8500 | 960.01 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 8 | 85 ~ 264 VAC | 24V | 12V | 24V | 24V | 5V | 24V | 8.3 A | 15 A | 3 A | 3 A | 6 A | 3 A | 885W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-BGCADG-P-A-DK00000AC/DC CNVT 2X24V 48V 5V 3X24V |
7326 | 960.01 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 8 | 85 ~ 264 VAC | 12V | 24V | 24V | 24V | 5V | 48V | 15 A | 3 A | 3 A | 8.3 A | 21 A | 4.17 A | 925W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-BBGCGD-P-A-DK00000AC/DC CNVT 48V 3X24V 12V 24V |
8417 | 960.01 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 8 | 85 ~ 264 VAC | 12V | 12V | 24V | 24V | 24V | 24V | 15 A | 15 A | 3 A | 3 A | 8.3 A | 3 A | 1000W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-CGCCHB-P-A-DK00000AC/DC CNVT 12V 5V 5X24V 1000W |
7395 | 960.01 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 8 | 85 ~ 264 VAC | 24V | 24V | 24V | 24V | 24V | 5V | 8.3 A | 3 A | 3 A | 8.3 A | 8.3 A | 6 A | 1000W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-BHDHBD-P-A-DK00000AC/DC 48V 12V 5V 24V 5V 24V 48V |
7014 | 960.01 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 8 | 85 ~ 264 VAC | 12V | 5V | 24V | 48V | 5V | 24V | 15 A | 6 A | 3 A | 4.17 A | 6 A | 3 A | 960W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
Tel