Mfr. Part # | Stock | Price | Quantity | Datasheet | Packaging | Series | ProductStatus | Type | NumberofOutputs | Voltage-Input | Voltage-Output1 | Voltage-Output2 | Voltage-Output3 | Voltage-Output4 | Voltage-Output5 | Voltage-Output6 | Current-Output1 | Current-Output2 | Current-Output3 | Current-Output4 | Current-Output5 | Current-Output6 | Power(Watts) | Applications | Voltage-Isolation | Efficiency | OperatingTemperature | Features | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
CX10S-BGGDBA-P-A-DK00000AC/DC CNVT 5V 12V 48V 4X24V 905W |
8195 | 960.01 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 8 | 85 ~ 264 VAC | 12V | 24V | 24V | 24V | 24V | 48V | 15 A | 3 A | 3 A | 3 A | 3 A | 4.17 A | 905W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-CAHBHD-P-A-DK00000AC/DC CNVT 48V 5V 24V 12V 2X5V |
7417 | 960.01 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 8 | 85 ~ 264 VAC | 24V | 5V | 5V | 24V | 12V | 5V | 8.3 A | 21 A | 6 A | 3 A | 15 A | 6 A | 885W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-BBHBDH-P-A-DK00000AC/DC CNVT 5V 24V 48V 2X12V 5V |
7788 | 960.01 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 8 | 85 ~ 264 VAC | 12V | 12V | 5V | 24V | 12V | 48V | 15 A | 15 A | 6 A | 3 A | 15 A | 4.17 A | 940W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-BBDHDH-P-A-DK00000AC/DC CNVT 5V 24V 48V 5V 12V 24V |
7975 | 960.01 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 8 | 85 ~ 264 VAC | 12V | 12V | 48V | 5V | 24V | 48V | 15 A | 15 A | 4.17 A | 6 A | 3 A | 4.17 A | 960W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-BHDBHB-P-A-DK00000AC/DC 12V 5V 24V 12V 5V 24V 48V |
7800 | 960.01 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 8 | 85 ~ 264 VAC | 12V | 5V | 24V | 48V | 12V | 5V | 15 A | 6 A | 3 A | 4.17 A | 15 A | 6 A | 940W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-AHGDDA-P-A-DK00000ACDC CNVT 5V 2X48V 24V 5V 2X24V |
8364 | 960.01 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 8 | 85 ~ 264 VAC | 5V | 5V | 24V | 24V | 24V | 48V | 21 A | 6 A | 3 A | 3 A | 3 A | 4.17 A | 830W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-BBHAHD-P-A-DK00000AC/DC CNVT 48V 5V 24V 5V 12V 5V |
7709 | 960.01 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 8 | 85 ~ 264 VAC | 12V | 12V | 5V | 24V | 5V | 5V | 15 A | 15 A | 6 A | 3 A | 21 A | 6 A | 865W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-AHDBAH-P-A-DK00000AC/DC 5V 24V 5V 12V 5V 24V 48V |
6740 | 960.01 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 8 | 85 ~ 264 VAC | 5V | 5V | 24V | 48V | 12V | 5V | 21 A | 6 A | 3 A | 4.17 A | 15 A | 21 A | 790W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-CADHGB-P-A-DK00000AC/DC CNVT 12V 2X24V 2X5V 24V |
7860 | 960.01 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 8 | 85 ~ 264 VAC | 24V | 5V | 48V | 5V | 24V | 24V | 8.3 A | 21 A | 4.17 A | 6 A | 3 A | 3 A | 905W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-CDBHCG-P-A-DK00000ACDC CNVT 3X24V 5V 48V 24V 1000W |
8369 | 960.01 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 8 | 85 ~ 264 VAC | 24V | 48V | 12V | 5V | 24V | 24V | 8.3 A | 4.17 A | 15 A | 6 A | 3 A | 8.3 A | 1000W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-BGBGBA-P-A-DK00000AC/DC CNVT 5V 12V 4X24V 12V 885W |
7551 | 960.01 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 8 | 85 ~ 264 VAC | 12V | 24V | 24V | 12V | 24V | 24V | 15 A | 3 A | 3 A | 15 A | 3 A | 3 A | 885W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-CDBHHD-P-A-DK00000AC/DC CNVT 48V 5V 24V 5V 48V 24V |
7938 | 960.01 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 8 | 85 ~ 264 VAC | 24V | 48V | 12V | 5V | 24V | 5V | 8.3 A | 4.17 A | 15 A | 6 A | 3 A | 6 A | 980W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-CCGDAH-P-A-DK00000AC/DC CNVT 5V 24V 5V 48V 2X24V |
8323 | 960.01 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 8 | 85 ~ 264 VAC | 24V | 24V | 24V | 24V | 48V | 5V | 8.3 A | 8.3 A | 3 A | 3 A | 4.17 A | 21 A | 925W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-CGAGCC-P-A-DK00000AC/DC CONVERTER 6X24V 5V 945W |
7092 | 960.01 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 8 | 85 ~ 264 VAC | 24V | 24V | 24V | 5V | 24V | 24V | 8.3 A | 3 A | 3 A | 21 A | 3 A | 3 A | 945W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-BAAGAH-P-A-DK00000AC/DC CNVT 5V 24V 5V 24V 5V 24V |
7778 | 960.01 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 8 | 85 ~ 264 VAC | 12V | 5V | 5V | 24V | 24V | 5V | 15 A | 21 A | 21 A | 3 A | 3 A | 21 A | 715W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-BAHAHC-P-A-DK00000AC/DC CNVT 24V 5V 24V 3X5V 790W |
6900 | 960.01 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 8 | 85 ~ 264 VAC | 12V | 5V | 5V | 24V | 5V | 5V | 15 A | 21 A | 6 A | 3 A | 21 A | 6 A | 790W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-CCGDAG-P-A-DK00000AC/DC CNVT 2X24V 5V 48V 2X24V |
8454 | 960.01 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 8 | 85 ~ 264 VAC | 24V | 24V | 24V | 24V | 48V | 5V | 8.3 A | 8.3 A | 3 A | 3 A | 4.17 A | 21 A | 945W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-BGGDDC-P-A-DK00000AC/DC CNVT 24V 2X48V 4X24V 1000W |
6858 | 960.01 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 8 | 85 ~ 264 VAC | 12V | 24V | 24V | 24V | 24V | 48V | 15 A | 3 A | 3 A | 3 A | 3 A | 4.17 A | 1000W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-AHGDDD-P-A-DK00000AC/DC CNVT 3X48V 24V 5V 2X24V |
8217 | 960.01 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 8 | 85 ~ 264 VAC | 5V | 5V | 24V | 24V | 24V | 48V | 21 A | 6 A | 3 A | 3 A | 3 A | 4.17 A | 925W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
CX10S-BAHAGC-P-A-DK00000AC/DC CONVERTER 3X24V 3X5V 810W |
7798 | 960.01 |
Add To CartInquiry Now |
![]() Datasheet |
Box | COOLX®1000 | Active | Enclosed | 8 | 85 ~ 264 VAC | 12V | 5V | 5V | 24V | 5V | 24V | 15 A | 21 A | 6 A | 3 A | 21 A | 3 A | 810W | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input |