Datasheet | Photo | Mfr. Part # | Stock | Price | Quantity | Packaging | Series | ProductStatus | Type | NumberofOutputs | Voltage-Input | Voltage-Output1 | Voltage-Output2 | Voltage-Output3 | Voltage-Output4 | Voltage-Output5 | Voltage-Output6 | Current-Output1 | Current-Output2 | Current-Output3 | Current-Output4 | Current-Output5 | Current-Output6 | Power(Watts) | Applications | Voltage-Isolation | Efficiency | OperatingTemperature | Features |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() Datasheet |
|
MVAC400-24AFTAC/DC CONVERTER 24V 250W |
5709 | 219.92 |
Add To CartInquiry Now |
Box | MVAC400 (400W) | Active | Open Frame | 1 | 90 ~ 264 VAC | 24V | - | - | - | - | - | 16.7 A | - | - | - | - | - | 250W (400W Forced Air) | ITE (Commercial), Medical | 1.5 kV | 93% | -10°C ~ 70°C (With Derating) | Hot Swappable, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input |
![]() Datasheet |
|
D1U54P-W-650-12-HB4CAC/DC CONVERTER 12V 650W |
4831 | 350.69 |
Add To CartInquiry Now |
Box | D1U54P-W-650 (650W) | Active | Front End | 1 | 90 ~ 264 VAC | 12V | - | - | - | - | - | 54.2 A | - | - | - | - | - | 650W | ITE (Commercial) | 3 kV | 94% | -40°C ~ 70°C | Hot Swappable, I²C™ Interface, Load Sharing, PFC, PMBus™, Remote On/Off, Remote Sense, Standby Output, Universal Input |
![]() Datasheet |
![]() |
PQU650-54AC/DC CONVERTER 54V 653W |
6926 | 216.88 |
Add To CartInquiry Now |
Box | PQU650 (650W) | Active | Open Frame | 1 | 90 ~ 264 VAC | 54V | - | - | - | - | - | 12.1 A | - | - | - | - | - | 653W | ITE (Commercial), Medical | 4 kV | 95% | -30°C ~ 70°C (With Derating) | Adjustable Output, Load Sharing, Remote Sense, Standby Output, Universal Input |
![]() Datasheet |
|
MVAC400-12AFDAC/DC CONVERTER 2X12V 5V 250W |
7231 | 219.92 |
Add To CartInquiry Now |
Box | MVAC400 (400W) | Active | Open Frame | 3 | 90 ~ 264 VAC | 12V | 12V | 5V | - | - | - | 33.3 A | 1 A | 2 A | - | - | - | 250W (400W Forced Air) | ITE (Commercial), Medical | 3 kV | 93% | -10°C ~ 70°C (With Derating) | Hot Swappable, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input |
![]() Datasheet |
|
MVAC400-24AFDAC/DC CONVERTER 24V 12V 5V 250W |
7160 | 219.92 |
Add To CartInquiry Now |
Box | MVAC400 (400W) | Active | Open Frame | 3 | 90 ~ 264 VAC | 24V | 12V | 5V | - | - | - | 16.7 A | 1 A | 2 A | - | - | - | 250W (400W Forced Air) | ITE (Commercial), Medical | 3 kV | 93% | -10°C ~ 70°C (With Derating) | Hot Swappable, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input |
![]() Datasheet |
![]() |
PQC250-36DRTAC/DC CONVERTER 36V 248W |
8464 | 127.87 |
Add To CartInquiry Now |
Box | PQC250 (250W) | Active | Open Frame | 1 | 90 ~ 264 VAC | 36V | - | - | - | - | - | 6.9 A | - | - | - | - | - | 248W | ITE (Commercial), Medical | 4 kV | 95% | -10°C ~ 70°C (With Derating) | Load Sharing, PFC, Remote Sense, Standby Output, Universal Input |
![]() Datasheet |
![]() |
PQC250-54DRTAC/DC CONVERTER 54V 248W |
7658 | 127.87 |
Add To CartInquiry Now |
Box | PQC250 (250W) | Active | Open Frame | 1 | 90 ~ 264 VAC | 54V | - | - | - | - | - | 4.6 A | - | - | - | - | - | 248W | ITE (Commercial), Medical | 4 kV | 95% | -10°C ~ 70°C (With Derating) | Load Sharing, PFC, Remote Sense, Standby Output, Universal Input |
![]() Datasheet |
![]() |
PQU1000-54AC/DC CONVERTER 54V 1000W |
7868 | 373.24 |
Add To CartInquiry Now |
Box | PQU1000 (1000W) | Active | Open Frame | 1 | 90 ~ 264 VAC | 54V | - | - | - | - | - | 18.5 A | - | - | - | - | - | 1000W | ITE (Commercial), Medical | 4 kV | 95% | -30°C ~ 70°C (With Derating) | Adjustable Output, Load Sharing, PFC, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() Datasheet |
![]() |
PQC250-24DRTAC/DC CONVERTER 24V 250W |
8534 | 127.87 |
Add To CartInquiry Now |
Box | PQC250 (250W) | Active | Open Frame | 1 | 90 ~ 264 VAC | 24V | - | - | - | - | - | 10.4 A | - | - | - | - | - | 250W | ITE (Commercial), Medical | 4 kV | 95% | -10°C ~ 70°C (With Derating) | Load Sharing, PFC, Remote Sense, Standby Output, Universal Input |
![]() Datasheet |
![]() |
D1U54P-W-1200-12-HA4PCAC/DC CONVERTER 12V 1200W |
8071 | 521.18 |
Add To CartInquiry Now |
Box | D1U54P-W-1200 (1200W) | Active | Front End | 1 | 90 ~ 264 VAC | 12V | - | - | - | - | - | 100 A | - | - | - | - | - | 1200W | ITE (Commercial) | 3 kV | 94% | 0°C ~ 60°C | Hot Swappable, I²C™ Interface, Load Sharing, PFC, Remote Sense, Standby Output, Universal Input |
![]() Datasheet |
![]() |
PQC250-54DAC/DC CONVERTER 54V 250W |
7388 | 121.39 |
Add To CartInquiry Now |
Box | PQC250 (250W) | Active | Open Frame | 1 | 90 ~ 264 VAC | 54V | - | - | - | - | - | 4.6 A | - | - | - | - | - | 250W | ITE (Commercial), Medical | 4 kV | 95% | -10°C ~ 70°C (With Derating) | Load Sharing, PFC, Remote Sense, Standby Output, Universal Input |
![]() Datasheet |
![]() |
PQU650M-12PAC/DC 650W, 6X4 U-CHANNEL, 12V O |
7798 | 202.69 |
Add To CartInquiry Now |
Box | PQU650M (650W) | Active | Open Frame | 1 | 90 ~ 264 VAC | 12V | - | - | - | - | - | 54.2 A | - | - | - | - | - | 650W | Medical | 4 kV | 94% | -30°C ~ 70°C (With Derating) | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input |
![]() Datasheet |
![]() |
PQU650M-24PAC/DC 650W, 6X4 U-CHANNEL, 24V |
8173 | 202.69 |
Add To CartInquiry Now |
Box | PQU650M (650W) | Active | Open Frame | 1 | 90 ~ 264 VAC | 24V | - | - | - | - | - | 27.1 A | - | - | - | - | - | 650W | Medical | 4 kV | 94% | -30°C ~ 70°C (With Derating) | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input |
![]() Datasheet |
![]() |
PQU1000-48AC/DC CONVERTER 48V 998W |
7906 | 373.24 |
Add To CartInquiry Now |
Box | PQU1000 (1000W) | Active | Open Frame | 1 | 90 ~ 264 VAC | 48V | - | - | - | - | - | 20.8 A | - | - | - | - | - | 998W | ITE (Commercial), Medical | 4 kV | 95% | -30°C ~ 70°C (With Derating) | Adjustable Output, Load Sharing, PFC, PMBus™, Remote Sense, Standby Output, Universal Input |
![]() |
|
MVAB120-28AC/DC CONVERTER 28V 75W |
7638 | 42.24 |
Add To CartInquiry Now |
Box | MVAB120 (120W) | Obsolete | Open Frame | 1 | 90 ~ 264 VAC | 28V | - | - | - | - | - | 4.29 A | - | - | - | - | - | 75W (120W Forced Air) | ITE (Commercial) | 3 kV | 90% | -10°C ~ 50°C | PFC, Universal Input |
![]() Datasheet |
![]() |
PQU650-24AC/DC CONVERTER 24V 650W |
6916 | 216.88 |
Add To CartInquiry Now |
Box | PQU650 (650W) | Active | Open Frame | 1 | 90 ~ 264 VAC | 24V | - | - | - | - | - | 27.1 A | - | - | - | - | - | 650W | ITE (Commercial), Medical | 4 kV | 95% | -30°C ~ 70°C (With Derating) | Adjustable Output, Load Sharing, Remote Sense, Standby Output, Universal Input |
![]() Datasheet |
![]() |
PQC250-24AC/DC CONVERTER 24V 250W |
8467 | 108.70 |
Add To CartInquiry Now |
Box | PQC250 (250W) | Active | Open Frame | 1 | 90 ~ 264 VAC | 24V | - | - | - | - | - | 10.4 A | - | - | - | - | - | 250W | ITE (Commercial), Medical | 4 kV | 95% | -10°C ~ 70°C (With Derating) | Load Sharing, PFC, Remote Sense, Standby Output, Universal Input |
![]() Datasheet |
![]() |
PQC250-12AC/DC CONVERTER 12V 250W |
8510 | 108.70 |
Add To CartInquiry Now |
Box | PQC250 (250W) | Active | Open Frame | 1 | 90 ~ 264 VAC | 12V | - | - | - | - | - | 20.8 A | - | - | - | - | - | 250W | ITE (Commercial), Medical | 4 kV | 95% | -10°C ~ 70°C (With Derating) | Load Sharing, PFC, Remote Sense, Standby Output, Universal Input |
![]() Datasheet |
|
MVAC400-12AFAC/DC CONVERTER 2X12V 5V 250W |
7743 | 219.92 |
Add To CartInquiry Now |
Box | MVAC400 (400W) | Active | Open Frame | 3 | 90 ~ 264 VAC | 12V | 12V | 5V | - | - | - | 33.3 A | 1 A | 2 A | - | - | - | 250W (400W Forced Air) | ITE (Commercial), Medical | 3 kV | 93% | -10°C ~ 70°C (With Derating) | Hot Swappable, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input |
![]() Datasheet |
|
MVAC400-24AFAC/DC CONVERTER 24V 12V 5V 250W |
7926 | 219.92 |
Add To CartInquiry Now |
Box | MVAC400 (400W) | Active | Open Frame | 3 | 90 ~ 264 VAC | 24V | 12V | 5V | - | - | - | 16.7 A | 1 A | 2 A | - | - | - | 250W (400W Forced Air) | ITE (Commercial), Medical | 3 kV | 93% | -10°C ~ 70°C (With Derating) | Hot Swappable, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input |