Mfr. Part # | Stock | Price | Quantity | Datasheet | Packaging | Series | ProductStatus | Type | NumberofOutputs | Voltage-Input | Voltage-Output1 | Voltage-Output2 | Voltage-Output3 | Voltage-Output4 | Voltage-Output5 | Voltage-Output6 | Current-Output1 | Current-Output2 | Current-Output3 | Current-Output4 | Current-Output5 | Current-Output6 | Power(Watts) | Applications | Voltage-Isolation | Efficiency | OperatingTemperature | Features | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
VOF-120C-12-CNFAC/DC CONVERTER 12V 114W |
7594 | 53.78 |
Add To CartInquiry Now |
![]() Datasheet |
Box | VOF-120C-CNF (120W) | Active | Enclosed | 1 | 85 ~ 264 VAC, 120 ~ 370 VDC | 12V | - | - | - | - | - | 9.5 A | - | - | - | - | - | 114W | Household Appliances, ITE (Commercial) | 4 kV | 94% | -40°C ~ 85°C (With Derating) | Adjustable Output, Standby Output, Universal Input |
![]() |
VOF-120C-15-CNFAC/DC CONVERTER 15V 114W |
8491 | 53.78 |
Add To CartInquiry Now |
![]() Datasheet |
Box | VOF-120C-CNF (120W) | Active | Enclosed | 1 | 85 ~ 264 VAC, 120 ~ 370 VDC | 15V | - | - | - | - | - | 7.6 A | - | - | - | - | - | 114W | Household Appliances, ITE (Commercial) | 4 kV | 94% | -40°C ~ 85°C (With Derating) | Adjustable Output, Standby Output, Universal Input |
![]() |
VOF-200C-12AC/DC CONVERTER 12V 199W |
7926 | 53.93 |
Add To CartInquiry Now |
![]() Datasheet |
Tray | VOF-200C (200W) | Active | Open Frame | 1 | 85 ~ 264 VAC, 120 ~ 370 VDC | 12V | - | - | - | - | - | 16.6 A | - | - | - | - | - | 199W | Household Appliances, ITE (Commercial) | 4 kV | 93% | -40°C ~ 70°C (With Derating) | Adjustable Output, Standby Output, Universal Input |
![]() |
VOF-200C-24AC/DC CONVERTER 24V 200W |
6825 | 53.93 |
Add To CartInquiry Now |
![]() Datasheet |
Tray | VOF-200C (200W) | Active | Open Frame | 1 | 85 ~ 264 VAC, 120 ~ 370 VDC | 24V | - | - | - | - | - | 8.33 A | - | - | - | - | - | 200W | Household Appliances, ITE (Commercial) | 4 kV | 94% | -40°C ~ 70°C (With Derating) | Adjustable Output, Standby Output, Universal Input |
![]() |
VOF-200C-27AC/DC CONVERTER 27V 200W |
8311 | 53.93 |
Add To CartInquiry Now |
![]() Datasheet |
Tray | VOF-200C (200W) | Active | Open Frame | 1 | 85 ~ 264 VAC, 120 ~ 370 VDC | 27V | - | - | - | - | - | 7.4 A | - | - | - | - | - | 200W | Household Appliances, ITE (Commercial) | 4 kV | 94% | -40°C ~ 70°C (With Derating) | Adjustable Output, Standby Output, Universal Input |
![]() |
VOF-200C-15AC/DC CONVERTER 15V 200W |
8383 | 53.93 |
Add To CartInquiry Now |
![]() Datasheet |
Tray | VOF-200C (200W) | Active | Open Frame | 1 | 85 ~ 264 VAC, 120 ~ 370 VDC | 15V | - | - | - | - | - | 13.3 A | - | - | - | - | - | 200W | Household Appliances, ITE (Commercial) | 4 kV | 93% | -40°C ~ 70°C (With Derating) | Adjustable Output, Standby Output, Universal Input |
![]() |
VMS-120C-12-CNFAC/DC CONVERTER 12V 114W |
7906 | 54.23 |
Add To CartInquiry Now |
![]() Datasheet |
Box | VMS-120C-CNF (120W) | Active | Enclosed | 1 | 85 ~ 264 VAC, 120 ~ 370 VDC | 12V | - | - | - | - | - | 9.5 A | - | - | - | - | - | 114W | Household Appliances, Medical | 4 kV | 94% | -40°C ~ 85°C (With Derating) | Adjustable Output, Standby Output, Universal Input |
![]() |
VMS-120C-27-CNFAC/DC CONVERTER 27V 120W |
6942 | 54.23 |
Add To CartInquiry Now |
![]() Datasheet |
Box | VMS-120C-CNF (120W) | Active | Enclosed | 1 | 85 ~ 264 VAC, 120 ~ 370 VDC | 27V | - | - | - | - | - | 4.44 A | - | - | - | - | - | 120W | Household Appliances, Medical | 4 kV | 95% | -40°C ~ 85°C (With Derating) | Adjustable Output, Standby Output, Universal Input |
![]() |
VMS-120C-36-CNFAC/DC CONVERTER 36V 120W |
6963 | 54.23 |
Add To CartInquiry Now |
![]() Datasheet |
Box | VMS-120C-CNF (120W) | Active | Enclosed | 1 | 85 ~ 264 VAC, 120 ~ 370 VDC | 36V | - | - | - | - | - | 3.33 A | - | - | - | - | - | 120W | Household Appliances, Medical | 4 kV | 94% | -40°C ~ 85°C (With Derating) | Adjustable Output, Standby Output, Universal Input |
![]() |
VMS-120C-15-CNFAC/DC CONVERTER 15V 114W |
8630 | 54.23 |
Add To CartInquiry Now |
![]() Datasheet |
Box | VMS-120C-CNF (120W) | Active | Enclosed | 1 | 85 ~ 264 VAC, 120 ~ 370 VDC | 15V | - | - | - | - | - | 7.6 A | - | - | - | - | - | 114W | Household Appliances, Medical | 4 kV | 94% | -40°C ~ 85°C (With Derating) | Adjustable Output, Standby Output, Universal Input |
![]() |
VMS-120C-48-CNFAC/DC CONVERTER 48V 120W |
7548 | 54.23 |
Add To CartInquiry Now |
![]() Datasheet |
Box | VMS-120C-CNF (120W) | Active | Enclosed | 1 | 85 ~ 264 VAC, 120 ~ 370 VDC | 48V | - | - | - | - | - | 2.5 A | - | - | - | - | - | 120W | Household Appliances, Medical | 4 kV | 94.5% | -40°C ~ 85°C (With Derating) | Adjustable Output, Standby Output, Universal Input |
![]() |
VMS-200C-15AC/DC CONVERTER 15V 200W |
7028 | 54.38 |
Add To CartInquiry Now |
![]() Datasheet |
Tray | VMS-200C (200W) | Active | Open Frame | 1 | 85 ~ 264 VAC, 120 ~ 370 VDC | 15V | - | - | - | - | - | 13.3 A | - | - | - | - | - | 200W | Household Appliances, Medical | 4 kV | 93% | -40°C ~ 70°C (With Derating) | Adjustable Output, Standby Output, Universal Input |
![]() |
VMS-200C-27AC/DC CONVERTER 27V 200W |
8134 | 54.38 |
Add To CartInquiry Now |
![]() Datasheet |
Tray | VMS-200C (200W) | Active | Open Frame | 1 | 85 ~ 264 VAC, 120 ~ 370 VDC | 27V | - | - | - | - | - | 7.4 A | - | - | - | - | - | 200W | Household Appliances, Medical | 4 kV | 94% | -40°C ~ 70°C (With Derating) | Adjustable Output, Standby Output, Universal Input |
![]() |
VMS-200C-12AC/DC CONVERTER 12V 199W |
7663 | 54.38 |
Add To CartInquiry Now |
![]() Datasheet |
Tray | VMS-200C (200W) | Active | Open Frame | 1 | 85 ~ 264 VAC, 120 ~ 370 VDC | 12V | - | - | - | - | - | 16.6 A | - | - | - | - | - | 199W | Household Appliances, Medical | 4 kV | 93% | -40°C ~ 70°C (With Derating) | Adjustable Output, Standby Output, Universal Input |
![]() |
VMS-200C-48AC/DC CONVERTER 48V 200W |
8044 | 54.38 |
Add To CartInquiry Now |
![]() Datasheet |
Tray | VMS-200C (200W) | Active | Open Frame | 1 | 85 ~ 264 VAC, 120 ~ 370 VDC | 48V | - | - | - | - | - | 4.16 A | - | - | - | - | - | 200W | Household Appliances, Medical | 4 kV | 94% | -40°C ~ 70°C (With Derating) | Adjustable Output, Standby Output, Universal Input |
![]() |
VMS-200C-24AC/DC CONVERTER 24V 200W |
8277 | 54.38 |
Add To CartInquiry Now |
![]() Datasheet |
Tray | VMS-200C (200W) | Active | Open Frame | 1 | 85 ~ 264 VAC, 120 ~ 370 VDC | 24V | - | - | - | - | - | 8.33 A | - | - | - | - | - | 200W | Household Appliances, Medical | 4 kV | 94% | -40°C ~ 70°C (With Derating) | Adjustable Output, Standby Output, Universal Input |
![]() |
VMS-200C-36AC/DC CONVERTER 36V 200W |
7847 | 54.38 |
Add To CartInquiry Now |
![]() Datasheet |
Tray | VMS-200C (200W) | Active | Open Frame | 1 | 85 ~ 264 VAC, 120 ~ 370 VDC | 36V | - | - | - | - | - | 5.56 A | - | - | - | - | - | 200W | Household Appliances, Medical | 4 kV | 94% | -40°C ~ 70°C (With Derating) | Adjustable Output, Standby Output, Universal Input |
![]() |
CFM100M075AC/DC CONVERTER 7.5V 101W |
7411 | 54.80 |
Add To CartInquiry Now |
![]() Datasheet |
Box | CFM100M (100W) | Active | Open Frame | 1 | 90 ~ 264 VAC | 7.5V | - | - | - | - | - | 13.4 A | - | - | - | - | - | 101W | ITE (Commercial), Medical | 5.656 kV | 87% | -20°C ~ 70°C (With Derating) | Adjustable Output, PFC, Remote Sense, Universal Input |
![]() |
VGS-320D-15AC/DC CONVERTER 15V 321W |
7934 | 56.03 |
Add To CartInquiry Now |
![]() Datasheet |
Box | VGS-320D | Active | Enclosed | 1 | 85 ~ 305 VAC, 120 ~ 430 VDC | 15V | - | - | - | - | - | 21.4 A | - | - | - | - | - | 321W | ITE (Commercial) | 4 kV | 89% | -30°C ~ 70°C (With Derating) | Adjustable Output, PFC |
![]() |
VGS-320D-5AC/DC CONVERTER 5V 300W |
7238 | 56.03 |
Add To CartInquiry Now |
![]() Datasheet |
Box | VGS-320D | Active | Enclosed | 1 | 85 ~ 305 VAC, 120 ~ 430 VDC | 5V | - | - | - | - | - | 60 A | - | - | - | - | - | 300W | ITE (Commercial) | 4 kV | 84% | -30°C ~ 70°C (With Derating) | Adjustable Output, PFC |