Mfr. Part # | Stock | Price | Quantity | Datasheet | Packaging | Series | ProductStatus | Type | NumberofOutputs | Voltage-Input | Voltage-Output1 | Voltage-Output2 | Voltage-Output3 | Voltage-Output4 | Voltage-Output5 | Voltage-Output6 | Current-Output1 | Current-Output2 | Current-Output3 | Current-Output4 | Current-Output5 | Current-Output6 | Power(Watts) | Applications | Voltage-Isolation | Efficiency | OperatingTemperature | Features | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
VMS-180C-27-CNFAC/DC CONVERTER 27V 180W |
8228 | 59.36 |
Add To CartInquiry Now |
![]() Datasheet |
Box | VMS-180C-CNF (180W) | Active | Enclosed | 1 | 85 ~ 264 VAC, 120 ~ 370 VDC | 27V | - | - | - | - | - | 6.66 A | - | - | - | - | - | 180W | Household Appliances, Medical | 4 kV | 94% | -40°C ~ 70°C (With Derating) | Adjustable Output, Standby Output, Universal Input |
![]() |
VMS-180C-48-CNFAC/DC CONVERTER 48V 180W |
7760 | 59.36 |
Add To CartInquiry Now |
![]() Datasheet |
Box | VMS-180C-CNF (180W) | Active | Enclosed | 1 | 85 ~ 264 VAC, 120 ~ 370 VDC | 48V | - | - | - | - | - | 3.75 A | - | - | - | - | - | 180W | Household Appliances, Medical | 4 kV | 94% | -40°C ~ 70°C (With Derating) | Adjustable Output, Standby Output, Universal Input |
![]() |
VMS-180C-15-CNFAC/DC CONVERTER 15V 180W |
7830 | 59.36 |
Add To CartInquiry Now |
![]() Datasheet |
Box | VMS-180C-CNF (180W) | Active | Enclosed | 1 | 85 ~ 264 VAC, 120 ~ 370 VDC | 15V | - | - | - | - | - | 12 A | - | - | - | - | - | 180W | Household Appliances, Medical | 4 kV | 93% | -40°C ~ 70°C (With Derating) | Adjustable Output, Standby Output, Universal Input |
![]() |
FSP350-F35-A12AC/DC CONVERTER 12V 200W |
4967 | 60.60 |
Add To CartInquiry Now |
![]() Datasheet |
Box | FSP350-F35 A (350W) | Active | Open Frame | 1 | 90 ~ 264 VAC | 12V | - | - | - | - | - | 16.7 A | - | - | - | - | - | 200W (350W Forced Air) | ITE (Commercial) | 500 V | 92% | -20°C ~ 70°C (With Derating) | PFC, Universal Input |
![]() |
TXLN 110-105AC/DC CONVERTER 5V 100W |
7237 | 60.96 |
Add To CartInquiry Now |
![]() Datasheet |
Box | TXLN 110 (110W) | Active | Enclosed | 1 | 88 ~ 264 VAC, 125 ~ 375 VDC | 5V | - | - | - | - | - | 20 A | - | - | - | - | - | 100W | ITE (Commercial) | 3 kV | 84% | -20°C ~ 70°C (With Derating) | Adjustable Output, Universal Input |
![]() |
TXLN 110-112AC/DC CONVERTER 12V 110W |
7266 | 60.96 |
Add To CartInquiry Now |
![]() Datasheet |
Box | TXLN 110 (110W) | Active | Enclosed | 1 | 88 ~ 264 VAC, 125 ~ 375 VDC | 12V | - | - | - | - | - | 9.2 A | - | - | - | - | - | 110W | ITE (Commercial) | 3 kV | 85% | -20°C ~ 70°C (With Derating) | Adjustable Output, Universal Input |
![]() |
TXLN 110-115AC/DC CONVERTER 15V 110W |
8670 | 60.96 |
Add To CartInquiry Now |
![]() Datasheet |
Box | TXLN 110 (110W) | Active | Enclosed | 1 | 88 ~ 264 VAC, 125 ~ 375 VDC | 15V | - | - | - | - | - | 7.3 A | - | - | - | - | - | 110W | ITE (Commercial) | 3 kV | 86% | -20°C ~ 70°C (With Derating) | Adjustable Output, Universal Input |
![]() |
CFM150M240AC/DC CONVERTER 24V 150W |
7145 | 60.97 |
Add To CartInquiry Now |
![]() Datasheet |
Box | CFM150M (150W) | Active | Open Frame | 1 | 90 ~ 264 VAC | 24V | - | - | - | - | - | 6.25 A | - | - | - | - | - | 150W | ITE (Commercial), Medical | 5.656 kV | 92% | -20°C ~ 70°C (With Derating) | Adjustable Output, PFC, Remote Sense, Universal Input |
![]() |
VOF-200C-12-CNFAC/DC CONVERTER 12V 199W |
7213 | 61.26 |
Add To CartInquiry Now |
![]() Datasheet |
Box | VOF-200C-CNF (200W) | Active | Enclosed | 1 | 85 ~ 264 VAC, 120 ~ 370 VDC | 12V | - | - | - | - | - | 16.6 A | - | - | - | - | - | 199W | Household Appliances, ITE (Commercial) | 4 kV | 93% | -40°C ~ 70°C (With Derating) | Adjustable Output, Standby Output, Universal Input |
![]() |
VOF-200C-27-CNFAC/DC CONVERTER 27V 200W |
8086 | 61.26 |
Add To CartInquiry Now |
![]() Datasheet |
Box | VOF-200C-CNF (200W) | Active | Enclosed | 1 | 85 ~ 264 VAC, 120 ~ 370 VDC | 27V | - | - | - | - | - | 7.4 A | - | - | - | - | - | 200W | Household Appliances, ITE (Commercial) | 4 kV | 94% | -40°C ~ 70°C (With Derating) | Adjustable Output, Standby Output, Universal Input |
![]() |
VOF-200C-15-CNFAC/DC CONVERTER 15V 200W |
8437 | 61.26 |
Add To CartInquiry Now |
![]() Datasheet |
Box | VOF-200C-CNF (200W) | Active | Enclosed | 1 | 85 ~ 264 VAC, 120 ~ 370 VDC | 15V | - | - | - | - | - | 13.3 A | - | - | - | - | - | 200W | Household Appliances, ITE (Commercial) | 4 kV | 93% | -40°C ~ 70°C (With Derating) | Adjustable Output, Standby Output, Universal Input |
![]() |
CFM150S360-BAC/DC CONVERTER 36V 120W |
6947 | 61.38 |
Add To CartInquiry Now |
![]() |
Box | CFM150S (150W) | Active | Open Frame | 1 | 90 ~ 264 VAC | 36V | - | - | - | - | - | 3.33 A | - | - | - | - | - | 120W | Household Appliances, ITE (Commercial), Medical | 3 kV | 94% | -30°C ~ 80°C (With Derating) | Adjustable Output, Baseplate, Universal Input |
![]() |
CFM150S280-BAC/DC CONVERTER 28V 120W |
7658 | 61.38 |
Add To CartInquiry Now |
![]() |
Box | CFM150S (150W) | Active | Open Frame | 1 | 90 ~ 264 VAC | 28V | - | - | - | - | - | 4.28 A | - | - | - | - | - | 120W | Household Appliances, ITE (Commercial), Medical | 3 kV | 94% | -30°C ~ 80°C (With Derating) | Adjustable Output, Baseplate, Universal Input |
![]() |
CFM150S480-BAC/DC CONVERTER 48V 120W |
7613 | 61.38 |
Add To CartInquiry Now |
![]() |
Box | CFM150S (150W) | Active | Open Frame | 1 | 90 ~ 264 VAC | 48V | - | - | - | - | - | 2.5 A | - | - | - | - | - | 120W | Household Appliances, ITE (Commercial), Medical | 3 kV | 94% | -30°C ~ 80°C (With Derating) | Adjustable Output, Baseplate, Universal Input |
![]() |
LOF225-20B15-CAC/DC CONVERTER 15V 140W |
8391 | 61.39 |
Add To CartInquiry Now |
![]() Datasheet |
Box | LOF225-20Bxx-C (225W) | Active | Enclosed | 1 | 85 ~ 264 VAC, 120 ~ 370 VDC | 15V | - | - | - | - | - | 9.33 A | - | - | - | - | - | 140W | Household Appliances, ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 70°C (With Derating) | Adjustable Output, PFC, Standby Output, Universal Input |
![]() |
LOF225-20B27-CAC/DC CONVERTER 27V 130W |
7236 | 61.39 |
Add To CartInquiry Now |
![]() Datasheet |
Box | LOF225-20Bxx-C (225W) | Active | Enclosed | 1 | 85 ~ 264 VAC, 120 ~ 370 VDC | 27V | - | - | - | - | - | 4.81 A | - | - | - | - | - | 130W | Household Appliances, ITE (Commercial), Medical | 4 kV | 94% | -40°C ~ 70°C (With Derating) | Adjustable Output, PFC, Standby Output, Universal Input |
![]() |
LOF225-20B48-CAC/DC CONVERTER 48V 140W |
8385 | 61.39 |
Add To CartInquiry Now |
![]() Datasheet |
Box | LOF225-20Bxx-C (225W) | Active | Enclosed | 1 | 85 ~ 264 VAC, 120 ~ 370 VDC | 48V | - | - | - | - | - | 2.91 A | - | - | - | - | - | 140W | Household Appliances, ITE (Commercial), Medical | 4 kV | 94% | -40°C ~ 70°C (With Derating) | Adjustable Output, PFC, Standby Output, Universal Input |
![]() |
EML30US36-SAC/DC CONVERTER 36V 30W |
7324 | 61.59 |
Add To CartInquiry Now |
![]() Datasheet |
Box | EML30 (30W) | Active | Enclosed | 1 | 85 ~ 264 VAC | 36V | - | - | - | - | - | 830 mA | - | - | - | - | - | 30W | Medical | 4 kV | 82% | -20°C ~ 70°C (With Derating) | DC Input Capable, Universal Input |
![]() |
VMS-200C-27-CNFAC/DC CONVERTER 27V 200W |
7130 | 61.71 |
Add To CartInquiry Now |
![]() Datasheet |
Box | VMS-200C-CNF (200W) | Active | Enclosed | 1 | 85 ~ 264 VAC, 120 ~ 370 VDC | 27V | - | - | - | - | - | 7.4 A | - | - | - | - | - | 200W | Household Appliances, Medical | 4 kV | 94% | -40°C ~ 70°C (With Derating) | Adjustable Output, Standby Output, Universal Input |
![]() |
VMS-200C-15-CNFAC/DC CONVERTER 15V 200W |
7214 | 61.71 |
Add To CartInquiry Now |
![]() Datasheet |
Box | VMS-200C-CNF (200W) | Active | Enclosed | 1 | 85 ~ 264 VAC, 120 ~ 370 VDC | 15V | - | - | - | - | - | 13.3 A | - | - | - | - | - | 200W | Household Appliances, Medical | 4 kV | 93% | -40°C ~ 70°C (With Derating) | Adjustable Output, Standby Output, Universal Input |
Tel